Prisma equipamentos.loja2.com.br - Equipamentos de Medição

Televendas:


Se Preferir, Preencha Nosso Formulário de Contato
e-Mail : prismaequipamentos.eletronicos@gmail.com
KIKUSUI TOS 7100 M INSULATION RESISTANCE TESTER/MEDIDOR DE ISOLAÇÃO
×
KIKUSUI TOS 7100 M INSULATION RESISTANCE TESTER/MEDIDOR DE ISOLAÇÃO
KIKUSUI TOS 7100 M INSULATION RESISTANCE TESTER/MEDIDOR DE ISOLAÇÃO
R$ 1.980,00
18× de R$ 143,85
vezesparcelatotal
sem jurosR$ 1.980,00R$ 1.980,00
R$ 1.034,65R$ 2.069,30
R$ 699,86R$ 2.099,58
R$ 532,57R$ 2.130,28
R$ 432,23R$ 2.161,15
R$ 365,38R$ 2.192,28
R$ 317,68R$ 2.223,76
R$ 281,95R$ 2.255,60
R$ 254,19R$ 2.287,71
10×R$ 232,00R$ 2.320,00
11×R$ 213,88R$ 2.352,68
12×R$ 198,79R$ 2.385,48
13×R$ 186,06R$ 2.418,78
14×R$ 175,16R$ 2.452,24
15×R$ 165,74R$ 2.486,10
16×R$ 157,51R$ 2.520,16
17×R$ 150,27R$ 2.554,59
18×R$ 143,85R$ 2.589,30
Você poderá escolher o número de parcelas ao concluir a compra.

* Isto é uma simulação, verifique o valor final das parcelas no intermediador de pagamentos.

KIKUSUI TOS 7100 M INSULATION RESISTANCE TESTER/MEDIDOR DE IDOLAÇÃO

The Kikusui TOS7100M is able to perform insulation resistance testing of electronic devices based on the Electrical Appliance Control Act as well as IEC, CEE, BS, VDE, CSA and other safety standards.

Features: Medidor de Isolaçao



Equipped with a Pass/fail judgement Function Test results can be evaluated easily by setting judgement reference values in advance
Use of a Dual Pointer Meter - Both judgement reference values and measured values can be read independently
Two Output Modes - In the NORMAL mode, the measuring voltage is interrupted and an NG alarm is released when an NG judgement has been made. In the CONTINUE mode, the measuring voltage is not interrupted even if an NG judgement is made, and an NG alarm is released while continuing to indicate measured values
Provided with Remote Control Function - Both test and reset operations can be remote controlled from the outside

Specifications: especificaçoes:

Rated Measuring Range 500/1000 V
Effective Measuring Range 500 V range: 1M to 1000M
1000 V range: 2M to 2000 M
Accuracy 1st effective measuring range: 5% of reading
2nd effective measuring range: 10% of reading
Measuring Terminal Voltage +5, -0% of rated measuring voltage when output terminal is open
Indicating Meter Dual pointer meter, with mirror
Results Judgement Pass/fail judgement
Limit Value Setting Range Arbitrary set within effective measuring range
Judgement Accuracy ±15% of set value for 1st effective measuring range
±20% of set value for 2nd effective measuring range
Judgement Waiting-Time Approx. 0.3 s
Output Mode Selection NORMAL/CONTINUE
Line Voltage 100V..10%, 50/60 Hz



Specifications:
Rated Measuring Range 500/1000 V
Effective Measuring Range 500 V range: 1M to 1000 M
1000 V range: 2M to 2000 M
Accuracy 1st effective measuring range: 5% of reading
2nd effective measuring range: 10% of reading
Measuring Terminal Voltage +5,-0% of rated measuring voltage when output terminal is open
Indicating Meter Dual pointer meter, with mirror
Results Judgement Pass/fail judgement
Limit Value Setting Range Arbitrary set within effective measuring range
Judgement Accuracy + 15% of set value for 1st effective measuring range
+ 20% of set value for 2nd effective measuring range
Judgement Waiting-Time Approx. 0.3 s
Output Mode Selection NORMAL/CONTINUE
Line Voltage 100V..10%, 50/60 Hz